Emergency Lighting Installers & Maintenance

Installation, testing and maintenance covering the full BS 5266 lifecycle — escape route lighting, open area (anti-panic) lighting, high-risk task lighting, and standby lighting.

UK companies listed
132
Average Google rating
4.2
Combined Google reviews
2,807
Towns covered
101

Emergency lighting in the UK is governed by BS 5266 (code of practice) and the related BS EN standards for individual luminaires (e.g. BS EN 60598-2-22). Every non-domestic premises with a fire evacuation plan requires a designed emergency lighting scheme — there is no "one size fits all" template. Coverage must include every escape route, every change of direction, every fire alarm call point, every first-aid point, every disabled-refuge area, and every open space exceeding 60 m².

Testing is prescriptive: a brief monthly functional test (operate the test key or self-test to verify each luminaire energises) and an annual full-discharge three-hour test. Records must be kept in the building’s fire safety logbook. BS 5266-1:2016 sets out the required illuminance levels — 1 lux on the centre line of an escape route is the minimum floor-level illuminance.

Modern emergency lighting increasingly uses self-testing luminaires with either central monitoring or distributed test regimes. This removes the manual element from monthly checks but still requires annual full-discharge testing and record-keeping. A good contractor will propose a test strategy that fits the building’s use — intensive care wards, for example, need every test scheduled around clinical activity.

Common findings from INFIRISK-listed inspection contractors: batteries aged beyond their five-year service life, luminaires blocked by signage or plant added after commissioning, and open-area lighting missed in mezzanines or plant rooms. A competent provider catches these on a 30-minute walk-through.

Frequently asked questions

What standard applies to emergency lighting in the UK?

BS 5266-1:2016 is the code of practice for emergency lighting of premises. Product standards sit alongside it — BS EN 60598-2-22 for luminaires and BS EN 50172 for emergency escape lighting systems.

How often should emergency lighting be tested?

Monthly functional test (brief operation), annual full-discharge three-hour test. Records must be kept.

How long do emergency lighting batteries last?

Typically 4–5 years for a sealed lead-acid or NiCd battery under normal UK conditions. LiFePO4 and modern lithium packs last longer but cost more up-front.

Do I need emergency lighting in a car park?

Covered car parks that form part of a building’s escape route require BS 5266 compliant emergency lighting. Open-air surface car parks generally do not.

Need emergency lighting installers & maintenance?

Tell us what you need and compare proposals from verified UK providers.

Get quotes

Looking to list your emergency lighting installers & maintenance business?

Verified profiles get featured ordering and credential chips. INFIRISK surfaces third-party accreditations next to your listing.

Claim or add a listing

Emergency Lighting Installers & Maintenance by location