Correct installation of fireblocks is essential for maintaining effective fire compartmentation and ensuring compliance with UK fire safety standards. This article explores the importance of proper fireblock installation, the risks associated with poor installation, and practical guidance for UK professionals.
The Role of Fireblocks in Building Safety
Fireblocks, particularly open state intumescent fireblocks, play a critical role in passive fire protection by maintaining compartmentation in buildings. These fireblocks allow for ventilation and drainage in rainscreen facades while preventing fire spread through concealed cavities. When exposed to heat, the intumescent material expands to seal gaps, thus inhibiting fire progression.
Horizontal open state mineral fibre fireblocks incorporating an intumescent strip are a relatively new passive fire protection solution for rainscreen facades. These products permit ventilation and drainage and inhibit fire spread once the intumescent material expands to fully seal the concealed cavity after heat activation at approximately 130°C. Decades of use across Europe have shown that these products must be appropriately fixed to the internal substrate to prevent displacement and compromise of the facade’s passive fire safety, ventilation, and drainage functionality.
Risks of Improper Installation
Improper installation of fireblocks can lead to significant safety risks. According to the International Fire & Safety Journal, poor fixing methods can cause fireblocks to detach during a fire, compromising compartmentation and potentially obstructing ventilation and drainage. This can result in thermal inefficiency and moisture management issues, as well as failure to form a complete seal against fire spread.
Buildings and facades are subject to movement. During a fire, heat-induced air pressure and thermal expansion place additional stress on brackets and fasteners. Without sufficient tensile strength or retention capability, they may fail, causing the open state intumescent fireblock to detach. This can cause various problems, including possible thermal efficiency and moisture management issues due to fallen fireblocks obstructing ventilation and drainage flow in the cavity.
Best Practices for Fireblock Installation
To mitigate these risks, it is crucial to use appropriate fixing methods. The International Fire & Safety Journal outlines three common approaches: direct through-fix to the substrate, mechanically fixed partial penetration brackets, and mechanically fixed full penetration brackets with bent tails. Each method has its advantages, but full penetration brackets are often preferred for their ability to securely retain fireblocks and facilitate easier inspection.
Full penetration brackets with bent tails firmly secure open state fireblocks to the substrate, preventing lateral movement and maintaining contact with the backing wall. They also transfer the fireblock’s weight to the inner leaf, reducing reliance on the bracket’s tensile strength. When fixed above the fireblock, the brackets create a balance between its outer face and the bent tails, increasing structural support and helping prevent sagging.
UK Building Codes and Standards
According to the International Fire & Safety Journal, UK building regulations such as Approved Document B require cavity barriers to be tightly fitted and mechanically fixed to withstand various stresses. This aligns with international standards, ensuring that fireblocks remain effective under fire conditions and building movements.
Statutory and voluntary guidance advocates for fireblocks to be mechanically fixed in position. The Centre for Window and Cladding Technology (CWCT) recommends full-depth steel spikes with turned-over tails to prevent cavity barriers from falling, losing effectiveness, or blocking drainage. This positive restraint is favoured over partial-depth spikes for greater security and easier inspection.
The correct installation of fireblocks affects a wide range of stakeholders, including building owners, facilities managers, fire safety professionals, and responsible persons. Ensuring that fireblocks are properly installed and maintained is crucial for the safety of building occupants and the integrity of the building structure. Poor installation can lead to increased risks of fire spread, which can have devastating consequences for both people and property.
Fire safety professionals must understand available products, fixing methods, and requirements to ensure projects follow best practices. Regular inspections and adherence to the latest standards and guidance are essential to maintaining high-quality installations and ensuring compliance with UK building codes.
What Happens Next
As the construction industry continues to evolve, the importance of proper fireblock installation remains paramount. Fire safety professionals should stay informed about the latest developments in fireblock technology and installation methods. Training and certification programmes can help ensure that professionals are equipped with the knowledge and skills needed to install fireblocks correctly and maintain compliance with UK regulations.
The Firestop Contractors International Association (FCIA) defines the ‘DIIM’ of Firestopping™ as the proper “Design, Installation, Inspection and Maintaining Protection of Firestop Systems.” This approach ensures that installed fire-resistance-rated and smoke-resistant assemblies have a better chance of performing as designed.
Practical Takeaways for UK Professionals
Ensure fireblocks are installed using appropriate mechanical fixings to maintain compartmentation.
Regularly inspect fireblock installations to confirm compliance with UK building codes.
Consider using full penetration brackets for easier inspection and greater security.
Stay informed about the latest standards and guidance to ensure high-quality installations.
Engage with training and certification programmes to enhance knowledge and skills in fireblock installation.